COVID-19 Protective Gear Masks
Particulate Respirator Mask Industrial N95 Cup Elastic Strap One Size Fits Most White NonSterile
Features
- This classic disposable N95 particulate respirator is designed to help provide comfortable, reliable worker respiratory protection against certain non-oil based particles
- NIOSH approved for at least 95 percent filtration efficiency against certain non-oil based particles
- Two-strap design with welded dual point attachment helps provide a secure seal
- Cushioning nose foam
- Lightweight construction promotes greater worker acceptance and may help increase wear time
Other Industrial Masks Comparison
Certification/ Class (Standard) | N95 (NIOSH-42C FR84) | FFP2 (EN 149-2001) | KN95 (GB2626-20 06) | P2 (AS/NZ 1716:2012) | Korea 1st Class (KMOEL - 2017-64) | DS (Japan JMHLW- Notification 214, 2018) |
---|---|---|---|---|---|---|
Filter performance – (must be ≥ X% efficient) | ≥ 95% | ≥ 94% | ≥ 95% | ≥ 94% | ≥ 94% | ≥ 95% |
Test agent | NaCl | NaCl and paraffin oil | NaCl | NaCl | NaCl and paraffin oil | NaCl |
Flow rate | 85 L/min | 95 L/min | 85 L/min | 95 L/min | 95 L/min | 85 L/min |
Total inward leakage (TIL)* – tested on human subjects each performing exercises | N/A | ≤ 8% leakage (arithmetic mean) | ≤ 8% leakage (arithmetic mean) | ≤ 8% leakage (individual and arithmetic mean) | ≤ 8% leakage (arithmetic mean) | Inward Leakage measured and included in User Instructions |
Inhalation resistance – max pressure drop | ≤ 343 Pa | ≤ 70 Pa (at 30 L/min) ≤ 240 Pa (at 95 L/min) ≤ 500 Pa (clogging) | ≤ 350 Pa | ≤ 70 Pa (at 30 L/min) ≤ 240 Pa (at 95 L/min) | ≤ 70 Pa (at 30 L/min) ≤ 240 Pa (at 95 L/min) | ≤ 70 Pa (w/valve) ≤ 50 Pa (no valve) |
Flow rate | 85 L/min | Varied – see above | 85 L/min | Varied – see above | Varied – see above | 40 L/min |
Exhalation resistance - max pressure drop | ≤ 245 Pa | ≤ 300 Pa | ≤ 250 Pa | ≤ 120 Pa | ≤ 300 Pa | ≤ 70 Pa (w/valve) ≤ 50 Pa (no valve) |
Flow rate | 85 L/min | 160 L/min | 85 L/min | 85 L/min | 160 L/min | 40 L/min |
Exhalation valve leakage requirement | Leak rate ≤ 30 mL/min | N/A | Depressurizatio n to 0 Pa ≥ 20 sec | Leak rate ≤ 30 mL/min | visual inspection after 300 L /min for 30 sec | Depressurizatio n to 0 Pa ≥ 15 sec |
Force applied | -245 Pa | N/A | -1180 Pa | -250 Pa | N/A | -1,470 Pa |
CO2 clearance requirement | N/A | ≤ 1% | ≤ 1% | ≤ 1% | ≤ 1% | ≤ 1% |
ENQUIRE | ENQUIRE | ENQUIRE | ENQUIRE | ENQUIRE | ENQUIRE |
Definitions
Filter performance – the filter is evaluated to measure the reduction in concentrations of specific aerosols in air that passes
through the filter.
Test agent – the aerosol that is generated during the filter performance test.
Total inward leakage (TIL) – the amount of a specific aerosol that enters the tested respirator facepiece via both filter
penetration and faceseal leakage, while a wearer performs a series of exercises in a test chamber.
Inward leakage (IL)– the amount of a specific aerosol that enters the tested respirator facepiece, while a wearer performs a
normal breathing for 3 minutes in a test chamber. The test aerosol size (count median diameter) is about 0.5 micro meter.
Pressure drop – the resistance air is subjected to as it moves through a medium, such as a respirator filter.