New & Reconditioned Diesel Engines for Sale

COVID-19 Protective Gear Masks

Particulate Respirator Mask Industrial N95 Cup Elastic Strap One Size Fits Most White NonSterile

Features

 

  • This classic disposable N95 particulate respirator is designed to help provide comfortable, reliable worker respiratory protection against certain non-oil based particles
  • NIOSH approved for at least 95 percent filtration efficiency against certain non-oil based particles
  • Two-strap design with welded dual point attachment helps provide a secure seal
  • Cushioning nose foam
  • Lightweight construction promotes greater worker acceptance and may help increase wear time

Other Industrial Masks Comparison

Certification/ Class (Standard)N95 (NIOSH-42C
FR84)
FFP2 (EN 149-2001)KN95 (GB2626-20 06)P2 (AS/NZ 1716:2012)Korea 1st Class (KMOEL - 2017-64)DS (Japan JMHLW-
Notification 214, 2018)
Filter performance – (must be ≥ X% efficient)≥ 95%≥ 94%≥ 95%≥ 94%≥ 94%≥ 95%
Test agentNaClNaCl and paraffin oilNaClNaClNaCl and paraffin oilNaCl
Flow rate85 L/min95 L/min85 L/min95 L/min95 L/min85 L/min
Total inward leakage (TIL)* – tested on human subjects each performing exercisesN/A≤ 8% leakage (arithmetic mean)≤ 8% leakage (arithmetic mean)≤ 8% leakage (individual and arithmetic mean)≤ 8% leakage (arithmetic mean)Inward Leakage measured and included in User Instructions
Inhalation resistance – max pressure drop≤ 343 Pa≤ 70 Pa (at 30 L/min)
≤ 240 Pa (at 95 L/min)
≤ 500 Pa (clogging)
≤ 350 Pa≤ 70 Pa (at 30 L/min)
≤ 240 Pa (at 95 L/min)
≤ 70 Pa (at 30 L/min)
≤ 240 Pa (at 95 L/min)
≤ 70 Pa (w/valve)
≤ 50 Pa (no valve)
Flow rate85 L/minVaried – see above85 L/minVaried – see aboveVaried – see above40 L/min
Exhalation resistance - max pressure drop≤ 245 Pa≤ 300 Pa≤ 250 Pa≤ 120 Pa≤ 300 Pa≤ 70 Pa (w/valve)
≤ 50 Pa (no valve)
Flow rate85 L/min160 L/min85 L/min85 L/min160 L/min40 L/min
Exhalation valve leakage requirementLeak rate ≤ 30 mL/minN/ADepressurizatio n to 0 Pa ≥ 20 secLeak rate ≤ 30 mL/minvisual inspection after 300 L /min for 30 secDepressurizatio n to 0 Pa ≥ 15 sec
Force applied-245 PaN/A-1180 Pa-250 PaN/A-1,470 Pa
CO2 clearance requirementN/A≤ 1%≤ 1%≤ 1%≤ 1%≤ 1%
ENQUIREENQUIREENQUIREENQUIREENQUIREENQUIRE

 

Definitions

Filter performance – the filter is evaluated to measure the reduction in concentrations of specific aerosols in air that passes
through the filter.

Test agent – the aerosol that is generated during the filter performance test.
Total inward leakage (TIL) – the amount of a specific aerosol that enters the tested respirator facepiece via both filter
penetration and faceseal leakage, while a wearer performs a series of exercises in a test chamber.

Inward leakage (IL)– the amount of a specific aerosol that enters the tested respirator facepiece, while a wearer performs a
normal breathing for 3 minutes in a test chamber. The test aerosol size (count median diameter) is about 0.5 micro meter.

Pressure drop – the resistance air is subjected to as it moves through a medium, such as a respirator filter.

  • Enquire Now!